Tempro Plus D 360 Manual: Wittmann

The internal valves will redirect compressed air to blow the water out of the mold back into the internal reservoir or drain. 4. Maintenance & Safety Protocols

: It utilizes a microprocessor controller with an accuracy of .

Select options such as "everything off," "cooling off," or "cooling safe temp purged off" (to purge the mold before turning off). 4. Maintenance and Troubleshooting

Inspect the cooling solenoid valve; descale the heat exchanger. Clogged mold cooling channels; dirty internal strainer.

Direct heating, and indirect or direct cooling, allowing for fast, responsive temperature regulation. Wittmann Tempro Plus D 360 Manual

Wittmann Tempro Plus D 360 Manual: Operating Guide & Technical Overview

The is a high-performance water temperature control unit (TCU). It is engineered for demanding injection moulding and industrial processing applications. Managing this equipment requires deep technical knowledge.

For detailed wiring or specific part replacement, you can refer to the Wittmann Download Center for official documentation. Temperature Controllers - WITTMANN Group

The system automatically fills the circuit, with integrated leakage and pressure monitoring. The internal valves will redirect compressed air to

Typically ranges from 9 kW to 36 kW depending on the specific model variant.

High-volume pumps equipped with magnetic couplings to eliminate leakage.

Frequently used operating modes can be accessed directly from touch fields at the bottom of the home screen.

The Tempro Plus D controller provides real-time visualization of operating parameters, diagnostics, and mold data. Initial Startup Sequence Turn on the main electrical isolator switch. Open all external water supply and drain valves. Select options such as "everything off," "cooling off,"

°C, it ensures that your process remains consistent, reducing scrap and improving part quality.

Never disconnect hoses while the unit is operating or when the temperature is above 60°C.

Flush the system to remove scale deposits and check pump impellers for wear. Common Troubleshooting Codes Fault Code / Symptom Possible Cause Corrective Action Low Water Level Insufficient feed pressure or leak Check water supply; inspect hoses for leaks. Over-Temperature Defective cooling valve or scaled heat exchanger Clean the heat exchanger; verify cooling valve operation. Motor Overload Pump rotation blocked or phase failure Check electrical phases; inspect pump for debris. Flow Alarm Air in system or closed mold valves Vent the system completely; open all process valves.